Output Definitions
- Passive output: NO-COM circuit closed, NC-COM open
- Active output: NC-COM circuit closed, NO-COM open
Functions by Device
Basic Controls
| Function | Eagle | Wizard | IS-87 / IS-87XL | Bodyguard | DK-12 |
|---|---|---|---|---|---|
| Lock | Lock | Lock | Lock | Lock | Not Used |
| Unlock | Unlock | Unlock | Unlock | Unlock | Not Used |
| Inquiry | Inquiry | Inquiry | Inquiry | Inquiry | Inquiry |
Sensitivity Settings (0 = min, 9 = max)
- Eagle: Default = 8
- Wizard (Motion): Default = 7
- IS-87 / IS-87XL: Default = 7
- Bodyguard: Default = 8 (closed), 8 (open)
- DK-12: Default = 8 (closed), 7 (open)
Hold Time (0–9)
- Range:
- 0.5 sec – 9 sec (most models)
- 1 sec – 10 sec (Bodyguard / DK-12)
- Defaults:
- Eagle: 0.5 sec
- Wizard: 0.5 sec
- IS-87: 0.5 sec
- Bodyguard: 1 sec
- DK-12: 1 sec
Relay Output (1–4)
Eagle
- Passive
- Active
- ON
- OFF
Default: 1
Wizard
| Setting | Relay | Transistor |
|---|---|---|
| 1 | Active | Passive |
| 2 | Passive | Active |
| 3 | Passive | Passive |
| 4 | Active | Active |
| Default: 4 |
IS-87 / IS-87XL / Bodyguard
- Passive
- Active
- ON
- OFF
Default: 1
DK-12
- Active
- Passive
- ON
- OFF
Default: 2
Auto Learn Time
Wizard (0–6)
| Setting | Time |
|---|---|
| 0 | 30 sec |
| 1 | 1 min |
| 2 | 2 min |
| 3 | 5 min |
| 4 | 10 min |
| 5 | 15 min |
| 6 | 20 min |
| Default: 1 |
Bodyguard / DK-12 (0–9)
| Setting | Time |
|---|---|
| 0 | 30 sec |
| 1 | 1 min |
| 2 | 2 min |
| 3 | 3 min |
| 4 | 5 min |
| 5 | 7 min |
| 6 | 10 min |
| 7 | 15 min |
| 8 | 20 min |
| 9 | 25 min |
| Default: 0 or 1 (model dependent) |
Detection Modes
Eagle / Wizard
- Bidirectional
- Unidirectional
- Unidirectional with MTF
Default: 3
IS-87 / IS-87XL
- Bidirectional
- Unidirectional approach
- Unidirectional depart
Default: 2
Pattern Width (Bodyguard / DK-12)
- Wide
- Middle
- Asymmetrical Left Narrow
- Asymmetrical Right Narrow
- Narrow Left
- Narrow Right
- Asymmetrical Left Wide
- Asymmetrical Right Wide
- Center Narrow
Default:
- Door closed: 1
- Door open: 2
Immunity Settings (1–3)
- Extreme sensitivity
- Normal sensitivity
- Decreased sensitivity
Default: 2
Additional Settings
Type of Detection (IS-87 / IS-87XL)
- Pedestrian & Vehicle
- Pedestrian only
- Default: 2
- IS-87XL: Pedestrian only
Pattern Depth (Bodyguard)
- Deep
- Medium
- Limited
Default: 1
Infrared Sensitivity (Wizard)
- Low gloss (high sensitivity)
- High gloss (low sensitivity)
Default: 2
Frequency (Bodyguard / DK-12)
- Bodyguard:
- Normal
- Random 1
- Random 2
Default: 2
- DK-12:
- High impulse
- Low impulse
Default: 1
Setup & Reset
Restore Default Settings
- Available on Eagle and IS-87
Wizard Setup (0–2)
- Infrared – Learn Background
- Normal mounting height (7–10 ft)
- Higher mounting height (10–12 ft)
DK-12 Setup (1–3)
- Door closed
- Door open
- Restore factory defaults
Notes