BEA ULTIMO Activation and Safety Sensor for Automatic Sliding Doors
Software Version 2.7 / Configuration Version 8.0
The BEA ULTIMO is an activation and safety sensor designed for automatic sliding doors. It combines microwave Doppler radar technology with active infrared (AIR) safety detection for reliable motion and presence sensing in commercial and industrial automatic door applications.
Product Overview
The ULTIMO sensor provides both activation and safety functionality for automatic sliding door systems. It features:
- Microwave Doppler radar motion detection
- Active infrared safety curtains
- LCD programming display
- Adjustable radar and infrared detection fields
- Built-in diagnostics and troubleshooting
- ULTI-SYNC infrared synchronization
- Configurable relay outputs
- External monitoring compatibility
What’s Included
The ULTIMO package includes:
- Sensor cover
- ULTIMO sensor
- Wiring harness
- Screw kit
- User guide
- Mounting template
Technical Specifications
Detection Technology
- Detection Mode: Motion and presence
- Technology: Microwave Doppler radar + Active Infrared (AIR)
- Radar Detection Speed: Minimum 2 in/sec
- AIR Response Time: Typical < 200 ms
Radar Specifications
- Frequency: 24.150 GHz
- Radiated Power: < 20 dBm EIRP
- Power Density: < 5 mW/cm²
- Detection Angle: 0°–45°
Infrared Specifications
- Spot Size: 2” × 2”
- Curtains: Up to 3
- Maximum Spots: 32 per curtain
- Curtain Angles: -3° to 11°
Mounting
- Recommended Mounting Height: 6’6” to 11’6”
- Typical Height: 7’2”
Electrical Specifications
Power Supply
- 12–24 VAC ±10%
- 12–30 VDC ±10%
- Maximum Power Consumption: < 3.2 W
Relay Outputs
Relay Output 1
- Electromechanical relay
- Max Current: 1 A
- Max Voltage: 30 VDC
Relay Output 2
- Solid-state relay
- Max Current: 400 mA
- Max Voltage: 42 VAC/VDC
Environmental Ratings
- Operating Temperature: -13°F to 131°F
- Humidity: 0–95% non-condensing
- Protection Rating: IP54
Safety Information
Installation Safety
- Installation should only be completed by trained personnel.
- The door control unit and header cover profile must be properly grounded.
- Test operation according to ANSI 156.10 before leaving the installation site.
- Unauthorized repairs void the warranty.
Maintenance Recommendations
- Clean optical components annually or more frequently if necessary.
- Do not use aggressive cleaning chemicals.
- Avoid highly reflective objects within the infrared field.
- Prevent excessive vibration during installation.
Mounting Instructions
Sensor Placement
Mount the sensor centered over the clear opening. The bottom of the sensor should not exceed 5 inches from the bottom of the door header.
Single Slider Installation
For single sliding doors, edge mounting is possible using IR Width settings 4 or 5.
Wiring Harness Routing
Use the supplied harness only. Route wiring away from high-voltage cables to avoid interference.
Wiring Connections
Power Supply Connections
| Wire Color | Function |
|---|---|
| Red | Power Supply |
| Black | Power Supply |
| Brown | Safety Input |
| Blue | Safety Input |
| White | COM |
| Yellow | N.C. Opening Input |
| Green | N.O. Opening Input |
| Purple | Test Output |
Radar Field Configuration
Radar Direction Modes
BI Mode
Bi-directional motion detection toward and away from the door.
UNI Mode
Unidirectional detection toward the door only.
MTF Mode
Motion tracking mode for slow-moving pedestrian traffic.
Radar Field Shape
- Wide
- Narrow
Radar Immunity
Adjustable immunity settings help prevent false detections caused by:
- Rain
- Lighting changes
- Environmental interference
Active Infrared Safety Field
Curtain Configurations
The ULTIMO supports multiple infrared curtain configurations depending on the application requirements.
Threshold Settings
Available threshold configurations:
- Setting 1
- Setting 2
- Setting 4
- Setting 5
Non-Threshold Settings
Available configurations:
- Setting 3
- Setting 6 (default)
- Setting 7
Infrared Curtain Adjustment
Visible Spot Alignment
Use the visible red spots to verify infrared curtain positioning.
Adjustment Procedure
- Activate visible spots.
- Adjust curtain angle using the red adjustment knob.
- Match the physical curtain position to the LCD configuration.
Infrared Field Width Settings
Available width options:
- Wide
- Standard
- Narrow
- Left Angled
- Right Angled
Always verify the detection field through walk-testing according to ANSI 156.10.
ULTI-SYNC Infrared Synchronization
ULTI-SYNC prevents infrared crosstalk between overlapping safety fields.
Features include:
- Automatic synchronization
- White LED synchronization indication
- Compatibility with nearby sensors
Sensor Setup
Push Button Setup
Press and hold the gray button for 2 seconds.
Remote Control Setup
Use the BEA remote control for wireless configuration and diagnostics.
Ensure the infrared field is clear before setup.
LCD Menu Settings
Infrared Settings
- IR Width
- IR Curtains
- IR Immunity
- IR Presence Time
- IR Frequency
Radar Settings
- Radar Field Size
- Radar Direction
- Radar Shape
- Radar Immunity
- Radar Reentry
Diagnostics
- Error Log
- IR Synchronization Status
- Power Supply Voltage
- Factory Reset
Troubleshooting
Red LED Errors
Fast Flash After Setup
Cause:
- Sensor sees the door during setup
Solution:
- Adjust AIR curtains away from the door
- Verify mounting height
Sporadic Red LED
Cause:
- Sensor vibration
- Environmental interference
Solution:
- Secure mounting hardware
- Adjust AIR curtain angles
Orange LED Errors
E1 Error
Internal fault detected.
E2 Error
Power supply voltage issue.
E3 Error
Radar communication error.
E4 Error
Insufficient AIR energy detected.
E5 Error
Excessive AIR energy detected.
E8 Error
Non-fatal or fatal AIR emitter error.
Green LED Errors
Sporadic Green LED
Possible causes:
- Rain
- Leaves
- Door movement
- Vibrations
- Unwanted moving objects
Solutions include adjusting radar immunity, field angle, and mounting stability.
Remote Control Functions
The BEA universal remote control supports:
- Parameter adjustment
- Password protection
- Factory reset
- Partial reset
- Value checking
- Multi-sensor programming
Accessories
Available Accessories
| Part Number | Description |
|---|---|
| 10ULTIMOSPACER | Spacer |
| 10URA | Universal Rain Accessory |
| 10UMB | Mounting Bracket |
| 10RETROFITSPACER | Retrofit Spacer Kit |
| 10REMOTE | Universal Remote Control |
Replacement Parts
| Part Number | Description |
|---|---|
| 10.1351 | Replacement Cover |
| 20.5349 | Replacement Harness |
Manufacturer Information
BEA, Inc.
- Tech Support: 1-800-407-4545
- Customer Service: 1-800-523-2462
- Website: www.BEAsensors.com