BEA WIZARD

BEA G3 Sensor

Combined Radar Activation & Active Infrared Safety Sensor

User Guide

Overview

The BEA G3 is a combined microwave motion and active infrared presence sensor designed for automatic pedestrian doors.

The sensor provides:

  • Motion activation using microwave radar
  • Presence safety detection using active infrared technology
  • Adjustable sensing fields
  • Self-monitoring infrared safety
  • Remote programmable configuration

The G3 is suitable for sliding and swinging automatic doors and complies with ANSI safety requirements.

Key Features

  • Combined motion + safety sensing
  • Adjustable radar detection field
  • Adjustable infrared safety curtains
  • Remote control configuration
  • Self-monitoring infrared technology
  • Multiple relay output configurations
  • Wide and narrow sensing patterns
  • One-way evening mode support
  • Intelli-Tracking software for improved reliability

Technical Specifications

General Specifications

Feature

Specification

Power Supply

12–24 VAC/VDC (-5% to +10%)

Power Consumption

< 3W

Operating Temperature

-30°F to +131°F

Protection Rating

NEMA 3S / IP54

Dimensions

10.4″ × 2.2″ × 1.9″

Cable Length

10 ft, 6-conductor

Housing Material

ABS & LURAN S

Housing Colors

Anthracite Gray, Aluminum, White

Motion Sensor Specifications

Feature

Specification

Technology

Microwave + Microprocessor

Frequency

24.125 GHz

Detection Speed

Minimum 2 in/sec

Response Time

< 128 ms

Adjustable Angle

15°–50°

Output Hold Time

0.5–9 sec

Detection Field Sizes

Pattern

Width

Depth

Wide

13 ft

6.5 ft

Narrow

6.5 ft

8.2 ft

Infrared Presence Sensor Specifications

Feature

Specification

Technology

Active Infrared

Number of Curtains

2

Spot Diameter

4″ max

Adjustable Angle

-4° to +4°

Detection Width

6.5 ft

Detection Depth

13.75 in

Safety Precautions

  • Disconnect power before wiring
  • Keep pedestrians clear during testing
  • Prevent moving door parts from contacting wiring
  • Follow ANSI A156.10 / A156.19 safety standards
  • Do not attempt internal repairs
  • Use ESD protection when handling electronics

Installation

Remove the Cover

  1. Gently pry the rear tab
  2. Remove the cover carefully
  3. Avoid damaging the housing clips

Mounting Guidelines

  • Mount 0″–2″ from the bottom of the header
  • Flush mounting is required for negative IR angles
  • Leave the cover off until setup is complete

Cable Routing

Route the cable around the internal plastic post to:

  • Prevent water intrusion
  • Improve cover installation
  • Reduce cable strain

Wiring

Wiring with Separate Activation & Safety Inputs

Wire Color

Function

Red

Power (+)

Black

Power (-)

White

Common

Green

Activation Output

Brown

Safety Common

Blue

Safety Output

Wiring with Shared Activation Input

In systems without a dedicated safety circuit:

  • Brown connects to White
  • Blue connects to Green

Mechanical Adjustments

Radar Detection Width

The G3 supports:

  • Wide radar antenna
  • Narrow radar antenna

Change antennas to alter motion field width.

Radar Detection Depth

Radar angle settings:

  • 15° = closer to door
  • 30° = standard
  • 45° = farther from door

Always walk-test after adjustment.

Infrared Curtain Width

Wide Pattern

  • 24 overlapping spots
  • Dual safety curtains

Narrow Pattern

  • 12 overlapping spots
  • Dual safety curtains

Install lens with smooth side outward.

Infrared Curtain Depth

Adjust using the IR curtain adjustment screw:

Adjustment

Result

Counterclockwise

Moves curtain farther

Clockwise

Moves curtain closer

Remote Control Programming

Common Adjustable Functions

Function

Range

Sensitivity

0–9

Hold Time

0.5–9 sec

Microwave Immunity

1–9

Infrared Immunity

1–2

Detection Mode

1–4

Output Configuration

1–4

Detection Modes

Mode

Description

1

Bidirectional

2

Unidirectional

3

Unidirectional with MTF

4

Reverse Unidirectional

Output Configuration

Mode

Motion Output

Presence Output

1

Active / NO

Passive / NC

2

Passive / NC

Active / NO

3

Passive / NC

Passive / NC

4

Active / NO

Active / NO

(Default = 4)

Infrared Curtain Setup

Assisted Setup

After installation or adjustment:

  1. Unlock sensor
  2. Press Setup
  3. Press 0

The sensor automatically:

  • Opens the door
  • Learns door movement
  • Configures the safety curtains

Manual Programming Without Remote

The G3 includes onboard programming buttons.

Parameters Available

Parameter

Function

1

Radar Sensitivity

2

Relay Hold Time

3

Output Configuration

4

Auto-Learn Presence

5

Detection Mode

6

Microwave Immunity

7

IR Immunity

10

IR Curtain Mode

11

Secondary Sensitivity

12

Height & Frequency

13

Output Redirection

14

Door Control Function

LED Indicators

LED Color

Meaning

Red

Presence Detection

Green

Motion Detection

Orange

Monitoring / Fault

Troubleshooting

Orange LED On

Possible causes:

  • IR saturation
  • Internal fault
  • Power instability

Solution

  • Relaunch setup
  • Reset power
  • Replace sensor if fault persists

Door Will Not Close

Possible causes:

  • Incorrect relay configuration
  • Faulty control switch
  • Wiring issue

Solution

  • Verify relay settings
  • Check control wiring
  • Test door controller independently

Door Keeps Recycling

Possible causes:

  • Sensor detecting the door
  • Vibrations
  • Moving objects in field

Solution

  • Adjust sensitivity
  • Reduce angle
  • Eliminate unwanted movement

Accessories

Accessory

Part Number

Ceiling Adapter

10WCA

Universal Rain Cover

10URC

Spotfinder

10SPOT

Cable Adapter

10IFBWIZARDII

One-Way Evening Mode

The G3 supports dual activation zones:

Zone

Depth

Output

Inner Zone

24″

Safety Circuit

Outer Zone

43″

Activation Circuit

By disabling the activation line:

  • Only the inner zone remains active
  • Door activates only when already open or moving

This feature supports ANSI compliance for one-way traffic applications.

Service Mode

The G3 can hold the door permanently open during service.

Remote Command

Press:

  • F2 → Hold Open
  • F2 + 1 → Return to Normal Operation

Compliance

The G3 complies with:

  • ANSI A156.10
  • ANSI A156.19
  • EMC 89/336/EEC
  • R&TTE 1999/5/EC