Besam 4000 – 88 CONTROL WIRING

How to install, adjust and power up Besam 4000 - 88 CONTROL WIRING Automatic Door System Wiring Diagram & Connection Reference

Besam 4000 Automatic Door System

88 Control Wiring Reference

Overview

The Besam 4000 automatic sliding door system uses the 88 Control Unit to manage:

  • Door activation
  • Safety inputs
  • Hold-open functionality
  • Locking devices
  • Emergency operation
  • Speed control
  • Key impulse activation
  • Photocell safety monitoring

The system integrates with multiple external devices including motion sensors, photocells, locking systems, and emergency units.

Main Components

Component

Description

Control Unit

Main operating controller

Power Supply

System transformer and power management

Emergency Unit

Emergency opening/closing system

Revolution Counter

Door movement monitoring

Locking Device

Electromechanical lock control

Photocells

Safety beam monitoring

Motion Sensors

Activation sensors

Push Button

Manual activation input

Motion Sensor Connections

The Besam 4000 supports:

  • Commander (RB1)
  • Selectscan
  • Intelliscan
  • PIR / Microwave activation sensors

Photocell Configurations

Supported Modes

Configuration

Description

PHO FS No.2 OFF

Photocell inactive

PHO FS No.2 ON

Photocell active

PHC FS No.2 OFF

Alternate photocell configuration

Notes

  • Only 4-wire photocells with transmitters and receivers are compatible
  • Refer to MK IIIA FS No.2 documentation for additional setup details

Terminal Block Connections

TB1 Connections

Terminal

Function

1–2

15–20V DC Power

3–4

Inner Impulse

5–6

Outer Impulse

7–8

Key Impulse

9–16

Control & sensor inputs

TB2 Connections

Terminal

Function

17–18

Hold Open

19–22

Stop Function

Sensor Wiring

Wire Color Reference

Color

Function

Red

Power

Black

Common / Ground

Green

Signal

White

Signal

Yellow

Auxiliary

Blue

Auxiliary

Impulse Inputs

The system includes multiple activation inputs.

Inner Impulse

Used for:

  • Interior activation sensors
  • Push plates
  • Motion detectors

Outer Impulse

Used for:

  • Exterior motion activation
  • Approach detection

Key Impulse

Used for:

  • Key switch activation
  • Secure access control
  • Timed entry systems

Hold Open Function

The Hold Open input allows the door to remain open continuously during:

  • High traffic periods
  • Maintenance
  • Emergency operation

Stop Function

The Stop Function input immediately halts door movement for:

  • Safety shutdown
  • Emergency stop control
  • Maintenance lockout

Emergency Unit

The emergency unit provides:

  • Emergency opening
  • Emergency closing
  • Backup operational control

Emergency Unit Inputs

Terminal

Function

B1

Emergency Control

B2

Emergency Control

Locking Device Integration

The system supports an external locking device connection.

Main Lock Connector

Wire

Function

Main

Lock Power

GND

Ground

+ / –

Control Voltage

Power Supply Specifications

Specification

Value

Main Power

115 VAC

Main Fuse

4A

Control Fuse

1.5T

Control Unit Settings

Speed Configuration

Setting

Description

HSO

High-Speed Opening

HSC

High-Speed Closing

LSO

Low-Speed Opening

LSC

Low-Speed Closing

TO

Partial Open Time

MP

Manual Open Time

Automatic Reset Feature

The Besam 4000 includes an automatic reset system.

Function

If no voltage is applied to the motor relay for approximately 10 seconds:

  • The computer automatically resets

Wiring Notes

  • Ensure proper grounding before startup
  • Disconnect locking devices before servicing
  • Verify photocell polarity during installation
  • Confirm all impulse inputs are properly isolated
  • Use recommended wire gauges for all control wiring

Recommended Cable Sizes

Connection

Cable Specification

Main Power

3 AWG 14

Sensor Inputs

4-wire low voltage

Push Button

Standard control cable

Locking Device

Shielded control cable recommended

Safety Recommendations

  • Disconnect power before servicing
  • Verify stop function operation during startup
  • Test all photocells before operation
  • Confirm emergency unit operation after installation
  • Inspect locking device operation regularly

Common System Functions

Door Opening Sequence

  1. Activation signal received
  2. Control unit energizes motor
  3. Door opens to programmed position
  4. Safety systems remain active

Door Closing Sequence

  1. Timer expires or command received
  2. Motor reverses direction
  3. Door closes to limit position
  4. Locking device engages if installed

Maintenance Recommendations

  • Inspect terminal connections periodically
  • Verify fuse condition
  • Test hold-open functionality
  • Confirm emergency operation