Besam CU2 REMOVE CU-HUB

How to install, adjust and power up Besam CU2 REMOVE CU-HUB Automatic Door System Wiring Diagram & Connection Reference

 

Besam SwingMaster CU-2 / CU-HUB Interface Wiring Diagram

LO21B/U Sensor ConfigurationOverview

This wiring diagram shows the connection of:

  • Besam SwingMaster CU-2 controller
  • CU-HUB interface
  • LO21B/U sensor module
  • Bodyguard safety sensor
  • Eagle sensor
  • Left and right side approach sensors
  • Left and right side safety sensors for automatic swing door applications.

System Components

Master Door Controller

Besam SwingMaster CU-2

Terminal Blocks:

TB1

Terminal

Function

1

IMP

2

0VDC

3

OPD

4

BC1

5

BC2

6

LOT

7

HLD

8

HNO

9

HNC

10

IHB

TB2

Terminal

Function

1

18VDC+

2

0VDC

3

KILL

4

0VDC

5

0VDC

6

Do Not Use

7

18VAC

8

18VAC

9

18VAC

Additional Connections:

  • J2
  • J3
  • CUHUB Interface
  • Sync Connection
  • Right-Hand Cam
  • Left-Hand Cam
  • Right-Hand Motor
  • Left-Hand Motor
  • 2A Fuse

Slave Door Controller

A second SwingMaster CU-2 may be configured as a slave controller for paired door systems.

Sensor Wiring

Left Approach Side Scan

Terminal

Function

1

Power

2

Power

3

COM

4

N.O.

5

N.C.

6

Inhibit +

7

Inhibit Ground

8

Empty

Left Safety Side Scan

Terminal

Function

1

Power

2

Power

3

COM

4

N.O.

5

N.C.

6

Inhibit +

7

Inhibit Ground

8

Empty

Right Approach Side Scan

Terminal

Function

1

Power

2

Power

3

COM

4

N.O.

5

N.C.

6

Inhibit +

7

Inhibit Ground

8

Empty

Bodyguard Sensor Connections

Terminal

Function

1

Power (Red)

2

Power (Black)

3

COM (White)

4

N.O. (Green)

5

N.C.

6

Data – (Brown)

7

Data + (Blue)

Eagle Sensor Connections

Wire Color

Function

Red

Power

Black

Power

White

COM

Green

N.O.

Brown

N.C.

LO21B/U Sensor Module

Wiring Colors

Wire Color

Function

Orange

HLD

Brown

BKO

Red

IMP

Yellow

OPD

Green

Range

Blue

Low

Violet

Hold

Grey

Auxiliary

White

Auxiliary

Red/White

Auxiliary

Black/White

Auxiliary

Default DIP Switch Settings

Factory default DIP switch settings are shown on the diagram for the LO21B/U module.

Safety Beam Input

The safety beam input accepts:

Dry Contact Only

If not used, cap off the Black/White wire.

Hold Open Switch

Switch positions:

  • OFF
  • ON
  • HOLD OPEN

Diagram shown in OFF position.

Installation Notes

Note 1

For simultaneous pair operation, ensure that the synchronization cable is connected between the master and slave controllers.

Note 2

Cap off the Black/White wire if it is not used.

Additional Diagram Note

The drawing includes a highlighted note:

“3 & 7 for stall”

which references specific controller terminal wiring for stall detection configuration.

Application

This configuration is intended for:

  • Besam SwingMaster CU-2 automatic swing doors
  • Paired or single-door installations
  • BEA LO21B/U sensor systems
  • Bodyguard safety sensors
  • Eagle motion sensors
  • Safety beam protection systems