Besam MP Programming

 

Besam SwingMaster MP Programming Guide

PMD (Programming Module Display) Setup & Functions

Document: SwingMaster MP – Adjustments and Troubleshooting
Document Number: US23-0186-01

Adjusting the CUP Control Unit

Important Notice

When installed and adjusted correctly, the Besam SwingMaster is a safe automatic power door operator. Incorrect settings can create safety hazards.

Startup & Adjustment Procedure

  1. Connect main power.
  2. Connect the PMD programming module to the CUP control unit.
  3. Enter the PIN code.
  4. Select Function 15 and set the correct operator type.
  5. Select Function 27 and verify the opening direction.
  6. Press Program Selector Button No. 4 (Auto).
  7. Press the Impulse Button.
  8. Allow the operator to complete a full open/close cycle.
  9. Adjust operating parameters if required.
  10. Install activation devices and accessories.
  11. Verify ANSI/BHMA A156.10 compliance.
  12. Disconnect the PMD.
  13. Install and secure the cover.

Adjustment Note

Always adjust balance force to the lowest value that still holds the door open against spring pressure.

Source: Page 1

Introduction to the PMD

The PMD (Programming Module Display) is used to program operating values into SwingMaster control units.

PMD Service Life

Model

Service Life

PMD-B

2,000 connections

PMD-C

400 connections

PMD-E

400 connections (restricted use)

The display shows the remaining service life.

If the display shows:

~71

the PMD has expired and must be returned for updating.

Source: Page 2

Default PIN Code

Factory PIN:

1234

Entering the PIN

  1. Connect PMD to control unit.
  2. Display shows:

Pin_

  1. Enter 1234.
  2. Press P.

The display then shows:

  • Control unit type (CUD or CUP)
  • Remaining PMD life
  • Status code or error code

Failed Attempts

After five incorrect PIN attempts:

~71

is displayed and the PMD becomes unusable until factory reset.

Source: Page 2

Changing the PIN Code

  1. Enter the existing PIN.
  2. Select Function 30.
  3. Set Value = b.
  4. Press P.
  5. Enter a new four-digit code.
  6. Press P again to save.

Important:

  • Forgotten PIN codes cannot be recovered.
  • If an error occurs, disconnect and reconnect the PMD and start over.

Source: Page 2

PMD Button Functions

Function Buttons ▲ ▼

Used to select Functions 01–99.

  • Up = next function
  • Down = previous function
  • Holding button scrolls continuously

Value Buttons + –

Used to change function values.


    • increases value
  • – decreases value
  • Holding button scrolls continuously

Program Button (P)

Transfers selected function values to the control unit.

Impulse Button (I)

Generates an opening impulse to the operator.

Reset Button (R)

Resets the control unit.

Hold for approximately 2 seconds.

Source: Page 3

Program Selector Functions

The PMD temporarily overrides the installed program selector.

Available Modes

Function

Description

Off

Door remains closed

Exit

Exit only

Open

Door remains open

Auto

Normal operation

Mat

Safety mat impulse

VP (IFD)

Presence detection

Key Impulse

Key switch activation

Low Speed Opening / Learn

Automatic VP-S sensitivity adjustment

Door Opening Angle >99°

Programs door opening angle

Source: Page 4

Pre-Programmed Run Programs

Function 98 provides six factory performance programs.

Run Program Values

Value

Program

01

Program 1

02

Program 2

03

Program 3 (Factory Default)

04

Program 4

05

Program 5

06

Program 6

Higher values increase operator performance.

Select only the minimum performance level required for safe operation.

Source: Page 4

Copying Programming Between Operators

User Values Only

Control Unit → PMD

  • Function 98
  • Value 99
  • Press P

Transfers Functions 01–27 from operator to PMD.

PMD → Control Unit

  • Function 98
  • Value 98
  • Press P

Transfers Functions 01–27 from PMD to operator.

All Values

Control Unit → PMD

  • Function 98
  • Value 97
  • Press P

Copies all programmed values.

PMD → Control Unit

  • Function 98
  • Value 96
  • Press P

Transfers all values to another operator.

Source: Page 5

PMD Functions and Values

Frequently Used Programming Functions

Function

Description

Range

Factory Setting

01

High Speed Opening

15–90%

45

02

Low Speed Opening

5–15%

10

03

Low Speed Distance Opening

5–40

20

04

High Speed Closing

15–60%

25

05

Low Speed Closing

5–15%

10

06

Low Speed Distance Closing

5–30

20

07

Lock Kick Additional

0–40%

00

08

Hold Open Time

0–60 sec

05

09

Key Open Time

0–60 sec

05

10

Door Opening Angle

30–99°

70

15

Operator Type

00–99

00

16

Push Reactivation

0–60 sec

02

17

Presence Monitoring

0–20

20

18

Mat Safety Monitoring

0–20

20

22

Balance Force (Open Door)

0–40

24

23

Hold Force (Closed Door)

0–40

00

25

Unlock Delay

0–5 sec

00

27

Door Opening Direction

A/B

A

30

Change PIN Code

Yes/No

A

98

Run Program

01–06

03

99

System Tests

01–05

—

Source: Page 6

Technician Quick Reference

First-Time Setup

  1. Enter PIN 1234
  2. Set Function 15 (Operator Type)
  3. Set Function 27 (Door Direction)
  4. Select Auto Mode
  5. Run an open/close cycle
  6. Adjust:
    • Opening speeds (01–03)
    • Closing speeds (04–06)
    • Hold-open time (08)
    • Door angle (10)
    • Balance force (22)
  7. Verify safety devices
  8. Test operation before returning to service