DOR-O-MATIC 96890-900 Safety Beam System
The DOR-O-MATIC 96890-900 Safety Beam System is an active infrared safety solution designed to enhance pedestrian protection in automatic door applications. Engineered to meet evolving safety requirements, the system utilizes microprocessed infrared technology to detect the presence of people and objects within the doorway, helping prevent unsafe door movement.
Its compact design allows for discreet installation within door frames while providing reliable performance in demanding commercial environments.
Key Features
- Active infrared presence detection
- Microprocessed control technology
- Compact, concealed installation
- Single-beam or dual-beam operation
- Adjustable detection range
- Fast response time
- Weather-resistant NEMA 4 enclosure
- Compatible with automatic sliding and swing door systems
- Normally Open (NO) and Normally Closed (NC) relay outputs
How It Works
The 96890-900 Safety Beam System creates an invisible infrared barrier across the door opening. When the beam is interrupted by a person or object, the control board sends a signal to the door operator, preventing unsafe movement or initiating a safety response.
Detection Method
- Presence sensing through beam interruption
- Single or crossed beam configurations
- Continuous monitoring during door operation
Technical Specifications
Detection Technology
Specification | Value |
Technology | Microprocessed Active Infrared |
Detection Method | Presence Detection by Beam Interruption |
Response Time | ≤ 40 ms |
Hold Time | 300 ms |
Alignment Tolerance | 8° |
Installation Requirements
Specification | Value |
Minimum Mounting Height | 1 ft above floor |
Minimum Beam Separation | 1 ft (crossed beams required) |
Distance from Door Plane | 1 inch |
Detection Range | 3 ft to 15 ft |
Electrical Specifications
Specification | Value |
Power Supply | 12–24 VAC ±10% |
Power Supply | 12–24 VDC (-5% / +30%) |
Current Consumption | Less than 100 mA |
Relay Output Ratings
Specification | Value |
Contact Type | NC / NO Relay Contacts |
Maximum Voltage | 50 VAC / 50 VDC |
Maximum Current | 1 Amp (Resistive) |
Maximum Switching Power | 30 WDC / 60 VA AC |
Environmental Specifications
Specification | Value |
Operating Temperature | -30°F to +131°F |
Ambient Light Immunity | 75,000 Lux |
Incandescent Light Immunity | 25,000 Lux |
Protection Rating | NEMA 4 (IP65) |
The system is also designed to meet electromagnetic compatibility requirements in accordance with CE standards.
Physical Specifications
Sensor Heads
- Compact cylindrical design
- Transparent housing
- Durable ABS construction
Control Board
- Compact control module
- Dip-switch configuration
- Integrated relay outputs
Cable Length Options
Available with:
- 15-foot cables
- 30-foot cables
(specified at time of order)
Available Beam Configurations
Single Beam Mode
Ideal for standard doorway protection applications.
Double Beam Mode
Provides enhanced safety coverage through crossed beam operation.
Benefits
- Increased detection reliability
- Improved obstacle recognition
- Greater compliance with automatic door safety requirements
Adjustable Settings
The control board includes dip-switch adjustments for customization.
Switch | ON | OFF |
1 | Double Beam Mode | Single Beam Mode |
2 | Active Mode (NC & COM) | Passive Mode (NO & COM) |
3 | Standard Range (15′) | Reduced Range (10′) |
4 | Test Mode | Normal Operation |
These settings allow installers to tailor performance for specific applications and operating conditions.
Installation Overview
Setup Procedure
- Remove the control box cover.
- Configure dip-switch settings as required.
- Connect emitter and receiver beam harnesses.
- Supply 12–24 VAC or VDC power.
- Connect relay outputs to the automatic door controller.
- Replace the control box cover and verify operation.
Single Beam Installation
When using a single beam pair:
- Connect to the “Beam A” terminal block.
- Set Switch 1 to the OFF position.
Visual Status Indicators
The control board features:
- Two red LED indicators
- LEDs illuminate when the beam barrier is interrupted
- Provides quick troubleshooting and status verification
Applications
The DOR-O-MATIC 96890-900 Safety Beam System is commonly used in:
- Automatic sliding doors
- Automatic swing doors
- Retail entrances
- Healthcare facilities
- Educational buildings
- Airports and transportation terminals
- Commercial office buildings
- Accessibility-compliant entrances
Benefits
- Enhanced pedestrian safety
- Fast response and detection
- Compact, discreet installation
- Reliable operation in varying lighting conditions
- Weather-resistant design for demanding environments
- Flexible configuration for multiple automatic door systems
The 96890-900 Safety Beam System provides a dependable safety solution for modern automatic door installations while maintaining a clean architectural appearance and meeting the operational demands of high-traffic commercial environments.