DOROMATIC 96890-084_Safety_Beam_system

DOR-O-MATIC 96890-900 Safety Beam System

 

The DOR-O-MATIC 96890-900 Safety Beam System is an active infrared safety solution designed to enhance pedestrian protection in automatic door applications. Engineered to meet evolving safety requirements, the system utilizes microprocessed infrared technology to detect the presence of people and objects within the doorway, helping prevent unsafe door movement.

Its compact design allows for discreet installation within door frames while providing reliable performance in demanding commercial environments.

Key Features

  • Active infrared presence detection
  • Microprocessed control technology
  • Compact, concealed installation
  • Single-beam or dual-beam operation
  • Adjustable detection range
  • Fast response time
  • Weather-resistant NEMA 4 enclosure
  • Compatible with automatic sliding and swing door systems
  • Normally Open (NO) and Normally Closed (NC) relay outputs

How It Works

The 96890-900 Safety Beam System creates an invisible infrared barrier across the door opening. When the beam is interrupted by a person or object, the control board sends a signal to the door operator, preventing unsafe movement or initiating a safety response.

Detection Method

  • Presence sensing through beam interruption
  • Single or crossed beam configurations
  • Continuous monitoring during door operation

Technical Specifications

Detection Technology

Specification

Value

Technology

Microprocessed Active Infrared

Detection Method

Presence Detection by Beam Interruption

Response Time

≤ 40 ms

Hold Time

300 ms

Alignment Tolerance

8°

Installation Requirements

Specification

Value

Minimum Mounting Height

1 ft above floor

Minimum Beam Separation

1 ft (crossed beams required)

Distance from Door Plane

1 inch

Detection Range

3 ft to 15 ft

Electrical Specifications

Specification

Value

Power Supply

12–24 VAC ±10%

Power Supply

12–24 VDC (-5% / +30%)

Current Consumption

Less than 100 mA

Relay Output Ratings

Specification

Value

Contact Type

NC / NO Relay Contacts

Maximum Voltage

50 VAC / 50 VDC

Maximum Current

1 Amp (Resistive)

Maximum Switching Power

30 WDC / 60 VA AC

Environmental Specifications

Specification

Value

Operating Temperature

-30°F to +131°F

Ambient Light Immunity

75,000 Lux

Incandescent Light Immunity

25,000 Lux

Protection Rating

NEMA 4 (IP65)

The system is also designed to meet electromagnetic compatibility requirements in accordance with CE standards.

Physical Specifications

Sensor Heads

  • Compact cylindrical design
  • Transparent housing
  • Durable ABS construction

Control Board

  • Compact control module
  • Dip-switch configuration
  • Integrated relay outputs

Cable Length Options

Available with:

  • 15-foot cables
  • 30-foot cables

(specified at time of order)

Available Beam Configurations

Single Beam Mode

Ideal for standard doorway protection applications.

Double Beam Mode

Provides enhanced safety coverage through crossed beam operation.

Benefits

  • Increased detection reliability
  • Improved obstacle recognition
  • Greater compliance with automatic door safety requirements

Adjustable Settings

The control board includes dip-switch adjustments for customization.

Switch

ON

OFF

1

Double Beam Mode

Single Beam Mode

2

Active Mode (NC & COM)

Passive Mode (NO & COM)

3

Standard Range (15′)

Reduced Range (10′)

4

Test Mode

Normal Operation

These settings allow installers to tailor performance for specific applications and operating conditions.

Installation Overview

Setup Procedure

  1. Remove the control box cover.
  2. Configure dip-switch settings as required.
  3. Connect emitter and receiver beam harnesses.
  4. Supply 12–24 VAC or VDC power.
  5. Connect relay outputs to the automatic door controller.
  6. Replace the control box cover and verify operation.

Single Beam Installation

When using a single beam pair:

  • Connect to the “Beam A” terminal block.
  • Set Switch 1 to the OFF position.

Visual Status Indicators

The control board features:

  • Two red LED indicators
  • LEDs illuminate when the beam barrier is interrupted
  • Provides quick troubleshooting and status verification

Applications

The DOR-O-MATIC 96890-900 Safety Beam System is commonly used in:

  • Automatic sliding doors
  • Automatic swing doors
  • Retail entrances
  • Healthcare facilities
  • Educational buildings
  • Airports and transportation terminals
  • Commercial office buildings
  • Accessibility-compliant entrances

Benefits

  • Enhanced pedestrian safety
  • Fast response and detection
  • Compact, discreet installation
  • Reliable operation in varying lighting conditions
  • Weather-resistant design for demanding environments
  • Flexible configuration for multiple automatic door systems

The 96890-900 Safety Beam System provides a dependable safety solution for modern automatic door installations while maintaining a clean architectural appearance and meeting the operational demands of high-traffic commercial environments.

How to install, adjust and power up DOROMATIC 96890-084_Safety_Beam_system Automatic Door System Wiring Diagram & Connection Reference
How to install, adjust and power up DOROMATIC 96890-084_Safety_Beam_system Automatic Door System Wiring Diagram & Connection Reference
How to install, adjust and power up DOROMATIC 96890-084_Safety_Beam_system Automatic Door System Wiring Diagram & Connection Reference