OA-Edge Secondary Activation & Stall Connection Matrix
Overview
This connection matrix provides wiring information for integrating the OA-Edge sensor with various automatic door operators for:
- Secondary Activation (Approach Side Reactivation) using Output 2
- Swing Side Stall/Safety Protection using Output 1
General Installation Notes
- Use Output 2 when mounting the sensor on the approach side.
- Use Output 1 when mounting the sensor on the swing side.
- Swing side stall functionality may require additional switches or wiring for 12–24 VAC/VDC inhibit depending on the operator.
SAM Requirements
SAM Required = NO
- Connections are suitable for both Fully Automatic and Knowing Act applications.
SAM Required = YES
- Connections are suitable for Fully Automatic applications.
- Knowing Act applications require a SAM Module or additional wiring for Output 2 (approach side sensor).
Power Harness Wire Colors
Power
Function | Wire Color |
12–24 VAC/VDC | White |
12–24 VAC/VDC | Brown |
Output 2 (Approach Side Reactivation)
Function | Wire Color |
COM | Green |
N/C | Yellow |
N/O | Grey |
Output 1 (Swing Side Stall)
Function | Wire Color |
COM | Pink |
N/C | Blue |
N/O | Red |
Manufacturer Wiring Reference
Besam
300/400
Wire | Connection |
White | Pin 7 |
Brown | Pin 8 |
Green | Pin 13 |
Grey | Pin 14 |
Blue | Pin 15 |
Red | Pin 16 |
SAM Required: Yes
Notes:
- On pairs with swing-side stall, run second red and blue wires to pins 17 and 18.
- On singles, jumper required from 17 to 18.
- If swing-side stall is not used, jumpers are required from 15 to 16 and 17 to 18.
- Use B switch for swing-side inhibit.
MP / CUP
SAM Required: No
Programming:
- F11 = 70
- F13 = A
- F14 = A
- F16 = 05
- F17 = 00
- F18 = 00
- F19 = B
- F20 = A
900 CU2
Notes:
- Swing-side stall input inhibits at backcheck.
- Adjust sensor angle/check zone to prevent false stall from walls or railings.
Dorma
EDA
Connection |
Any +24V |
GND |
APPR |
SWING |
SAM Required: No
ED-400 / ED-700 (New Style)
Same as EDA.
ED-700 (Old Style)
Uses CN2 connector pins.
Notes:
- Set LOUT potentiometer to cease lockout within 10° of full close.
Doromatic
Astro, Mid & Senior
SAM Required: Yes
Notes:
- Select Supernova Slow or Supernova Stop for stall function (typically settings 5 or 6).
- Mid & Senior models do not support stall.
Gyrotech / Nabco
300/400 Analog
SAM Required: Yes
Notes:
- Set control slide switch to Swing Safe for stall functionality.
Magnum Control
SAM Required: Yes
U-19 Control
Notes:
- For Knowing Act applications use SAM or wire for night mode.
- Contact OPTEX Technical Support for details.
Horton
4160 Control
SAM Required: Yes
Notes:
- For simultaneous pairs contact OPTEX Technical Support.
4190 Control
SAM Required: No
Notes:
- Adjust 4190 LOUT to remain active during closing within 10° of full close.
Hunter
FA-8 Old Style
SAM Required: Yes
FA-8 New Style
SAM Required: Yes
Digital 09827
SAM Required: Yes
Notes:
- Set LED1 FUNCTION to “A”.
- Set LED2 to ON.
- Provides swing-side inhibit at backcheck.
KM / Record
2000 B Control
Contact OPTEX for connection details.
K-Control
SAM Required: Yes
8000 / 6100
SAM Required: No
Notes:
- Remove jumper when sensor is connected to pins 10 & 11.
- Remove jumper when sensor is connected to pins 11 & 12.
LCN
2#00 / 9#00 Series
SAM Required: No
Notes:
- Use OPTEX Special Harness Kit:
- Part Number: Edge-LCN
4600 Series
SAM Required: No
Notes:
- No stall input available on control.
Stanley
L-Shape Control
SAM Required: Yes
Notes:
- Verify field color coding for pins 3 and 6.
- Set Stanley control to Timer Logic.
MP Control (HDLE)
SAM Required: Yes
Notes:
- Magic Force AUX cam switch may be used to inhibit swing-side sensor.
- Magicswing controls with jumper between terminals 6 and 8 may use breakout status switch for inhibit.
MC-521 Control
SAM Required: Yes
Notes:
- Safety Logic must be set to Sensor.
- AUX cam switch may be used to inhibit swing-side sensor.
Tormax
TDA
SAM Required: No
TTX2 Smart Drive (Without OHP)
SAM Required: No
Notes:
- Set Solid 2 to Flashing 5.
- Simultaneous pairs require Tormax cable #406079.
TTX2 Smart Drive (With OHP Sensor)
SAM Required: No
Notes:
- Set Solid 2 to Flashing 2.
- Set Solid 4 to Flashing 2.
- Simultaneous pairs require Tormax cable #406079.
iMotion 1301 / 1401 / TN110
SAM Required: No
Notes:
- Contact OPTEX for J6 blue-wire details.