E-PLEX 50xx/30xx Quick Reference Guide
Enter Programming Mode
To begin programming:
# Master Code #
The Master Code is always 8 digits.
Configuration Commands
Change Master Code
000#
MMMMMMMM#
MMMMMMMM#
Changes the Master User Access Code (8 digits).
Set Date
001#
MMDDYY#
MMDDYY#
Parameter | Range |
MM | 01–12 |
DD | 01–31 |
YY | 00–99 |
Set Time
002#
HHMM#
HHMM#
Parameter | Range |
HH | 00–23 |
MM | 00–59 |
Set Lock ID
003#
NNNN#
Parameter | Range |
NNNN | 0000–9999 |
Set Unlock Time
004#
TT#
Parameter | Range |
TT | 02–20 seconds |
Set Passage Mode Timeout
005#
TT#
Parameter | Description |
01–24 | Duration in hours |
00 | No time limit |
Set Tamper Time
006#
TT#
Parameter | Range |
TT | 00–90 seconds |
Set Tamper Wrong Try Limit
007#
TT#
Parameter | Range |
TT | 03–09 attempts |
Set Buzzer Volume
008#
VV#
Value | Setting |
00 | Off |
01 | Low |
02 | Normal |
03 | High |
Modify Access Code Length
009#
LL#
Value | Length |
04–08 | Digits |
Factory Reset
099#
Resets the lock to factory defaults except access code length.
The following users are retained if already programmed:
- Master User
- Manager User
- Access Users
User Management
Add / Modify User
100#
NNN#
UUUU#
UUUU#
Parameter | Description |
NNN | User ID (001–299) |
UUUU | Access Code (4–8 digits) |
Add / Modify Manager
101#
NNN#
UUUU#
UUUU#
Manager Access Code.
Add / Modify Service User
102#
NNN#
UUUU#
UUUU#
HH#
Parameter | Description |
HH | 01–24 hours |
00 | One-time entry |
Modify M-Unit User
103#
UUUU#
UUUU#
Updates the M-Unit User Code.
Delete Users
Delete User
200#
NNN#
Delete User Access Code.
Delete Manager
201#
NNN#
Delete Manager Access Code.
Delete Service User
202#
NNN#
Delete Service User Access Code.
Delete All Users
299#
Deletes all User Access Codes except:
- Master User
- Manager User
- M-Unit User
Activate Users
Activate User
300#
NNN#
Activate User ID 001–299.
Activate Manager
301#
NNN#
Activate Manager User.
Activate Service User
302#
NNN#
Activate Service User.
Activate M-Unit User
303#
Activate M-Unit User Code.
Activate All Users
398#
Activates all users except:
- Master User
- Manager User
- M-Unit User
Passage Mode
399#
P#
Value | Function |
0 | Disable Passage Mode |
1 | Enable Passage Mode |
Deactivate Users
Deactivate User
400#
NNN#
Deactivate User Access Code.
Deactivate Manager
401#
NNN#
Deactivate Manager Access Code.
Deactivate Service User
402#
NNN#
Deactivate Service User Access Code.
Deactivate M-Unit User
403#
Deactivate M-Unit User Code.
Deactivate All Users
498#
Deactivates all users except:
- Master User
- Manager User
- M-Unit User
Lockout Mode
499#
L#
Value | Function |
0 | Disable Lockout Mode |
1 | Enable Lockout Mode |
Note: Master User is not affected by Lockout Mode.
Diagnostics
Manual Diagnostic
500#
1234567890*#
Runs manual diagnostics.
Communications
Communication Startup
900#
Starts communication mode.
LED Status Reference
Condition | Green LED | Red LED |
Valid button press | ON | OFF |
Access granted | ON | OFF |
Access denied | OFF | ON |
Valid programming entry | ON | OFF |
Invalid programming entry | OFF | ON |
Tamper shutdown active | OFF | ON |
Communication in progress | Alternate | Alternate |
Battery Low + Access Granted | ON | ON |
Privacy Activated | OFF | ON |
Privacy Deactivated | ON | OFF |
These indicators help diagnose lock status, programming success, tamper conditions, battery state, and communication activity.