Eplex Quick Reference Guide

E-PLEX 50xx/30xx Quick Reference Guide


Enter Programming Mode

To begin programming:

# Master Code #

The Master Code is always 8 digits.

Configuration Commands

Change Master Code

000#
MMMMMMMM#
MMMMMMMM#

Changes the Master User Access Code (8 digits).

Set Date

001#
MMDDYY#
MMDDYY#

Parameter

Range

MM

01–12

DD

01–31

YY

00–99

Set Time

002#
HHMM#
HHMM#

Parameter

Range

HH

00–23

MM

00–59

Set Lock ID

003#
NNNN#

Parameter

Range

NNNN

0000–9999

Set Unlock Time

004#
TT#

Parameter

Range

TT

02–20 seconds

Set Passage Mode Timeout

005#
TT#

Parameter

Description

01–24

Duration in hours

00

No time limit

Set Tamper Time

006#
TT#

Parameter

Range

TT

00–90 seconds

Set Tamper Wrong Try Limit

007#
TT#

Parameter

Range

TT

03–09 attempts

Set Buzzer Volume

008#
VV#

Value

Setting

00

Off

01

Low

02

Normal

03

High

Modify Access Code Length

009#
LL#

Value

Length

04–08

Digits

Factory Reset

099#

Resets the lock to factory defaults except access code length.

The following users are retained if already programmed:

  • Master User
  • Manager User
  • Access Users

User Management

Add / Modify User

100#
NNN#
UUUU#
UUUU#

Parameter

Description

NNN

User ID (001–299)

UUUU

Access Code (4–8 digits)

Add / Modify Manager

101#
NNN#
UUUU#
UUUU#

Manager Access Code.

Add / Modify Service User

102#
NNN#
UUUU#
UUUU#
HH#

Parameter

Description

HH

01–24 hours

00

One-time entry

Modify M-Unit User

103#
UUUU#
UUUU#

Updates the M-Unit User Code.

Delete Users

Delete User

200#
NNN#

Delete User Access Code.

Delete Manager

201#
NNN#

Delete Manager Access Code.

Delete Service User

202#
NNN#

Delete Service User Access Code.

Delete All Users

299#

Deletes all User Access Codes except:

  • Master User
  • Manager User
  • M-Unit User

Activate Users

Activate User

300#
NNN#

Activate User ID 001–299.

Activate Manager

301#
NNN#

Activate Manager User.

Activate Service User

302#
NNN#

Activate Service User.

Activate M-Unit User

303#

Activate M-Unit User Code.

Activate All Users

398#

Activates all users except:

  • Master User
  • Manager User
  • M-Unit User

Passage Mode

399#
P#

Value

Function

0

Disable Passage Mode

1

Enable Passage Mode

Deactivate Users

Deactivate User

400#
NNN#

Deactivate User Access Code.

Deactivate Manager

401#
NNN#

Deactivate Manager Access Code.

Deactivate Service User

402#
NNN#

Deactivate Service User Access Code.

Deactivate M-Unit User

403#

Deactivate M-Unit User Code.

Deactivate All Users

498#

Deactivates all users except:

  • Master User
  • Manager User
  • M-Unit User

Lockout Mode

499#
L#

Value

Function

0

Disable Lockout Mode

1

Enable Lockout Mode

Note: Master User is not affected by Lockout Mode.

Diagnostics

Manual Diagnostic

500#
1234567890*#

Runs manual diagnostics.

Communications

Communication Startup

900#

Starts communication mode.

LED Status Reference

Condition

Green LED

Red LED

Valid button press

ON

OFF

Access granted

ON

OFF

Access denied

OFF

ON

Valid programming entry

ON

OFF

Invalid programming entry

OFF

ON

Tamper shutdown active

OFF

ON

Communication in progress

Alternate

Alternate

Battery Low + Access Granted

ON

ON

Privacy Activated

OFF

ON

Privacy Deactivated

ON

OFF

These indicators help diagnose lock status, programming success, tamper conditions, battery state, and communication activity.